Solar cable

Stäubli cable-coubler MC4

DownloadDatasheet PDF Stäubli cable-coubler MC4 Fast moving technology Photovoltaic main catalog Solarline | Connectors for renewable energy PLUG CONNECTORS Advantages... read more

Description

Download
Datasheet PDF

Stäubli cable-coubler MC4

Fast moving technology

Photovoltaic main catalog
Solarline | Connectors for renewable energy

PLUG CONNECTORS
Advantages of the MC4 connector range


Overview of plug connectors


1) Certifications are in some cases limited to specific types or still pending. Details are given on the relevant product pages.

Female and male cable coupler MC4
Female and male cable coupler as individual part (including insulating part)

Note:
For more detailed information concerning the suitable cable gland range, please consult MA231

 

■ Snap-in lock
■ In accordance with NEC 2014, requires a tool to open
■ Proven MULTILAM technology with high long-term stability, which ensures con-sistently low performance loss through-out the entire service life of the plug connector
■ Tried and tested plug connectors, over 15 years of experience in the field
■ Available for assembly with cross- sections of 10 mm²
■ Also available as ready made leads
■ Mating compatibility with MC4 connec-tor family
■ Leads made to customer’s specifications

Technical data
Connector system Ø 4 mm
1000 V DC (IEC 62852)
Rated voltage 1500 V DC (2Pfg2330)¹⁾
1500 V DC (UL)²⁾
22.5 A (2.5 mm²) 39 A (4 mm²/6 mm²)
Rated current TÜV (85°C)
45 A (10 mm²)
30 A (14 AWG) 30 A (12 AWG/10 AWG)
Rated current UL
50 A (8 AWG)
12 kV (1000 V DC (TÜV))
Rated impulse voltage
16 kV (1500 V DC (TÜV))
-40°C…+85°C (TÜV)
Ambient temperature range
-40°C…+75°C (UL)
Upper limiting temperature 105°C (TÜV)
Degree of protection, mated IP65, IP68 (1 h / 1 m)
unmated IP2X
Overvoltage category / Pollution degree CATIII / 3
Contact resistance of plug connectors ≤ 0.25 mΩ
Safety class 1000 V DC: II
1500 V DC: 0
Contact system MULTILAM
Type of termination Crimping
Contact material Copper, tin plated
Insulation material PC / PA
Locking system (UL) Locking type
Flame class UL94-V0
Ammonia resistance (acc. to DLG) 1500 h, 70°C / 70% RH, 750 ppm
Salt mist spray test, degree of severity 6 IEC 60068-2-52
TÜV-Rheinland certified, R60127190 3)
in accordance with IEC 62852
TÜV-Rheinland certified, R60087448
in accordance with 2PfG2330
UL recognized component, E343181
in accordance with UL 6703
CSA certified, in accordance with UL 6703 250725
CQC certified according CNCA/CTS0002-2012 CQC16024138286

1) 2Pfg2330: only approved for locations with restricted access
2) for selected configurations; see assembly instructions MA231 for details
3) For PV junction boxes in accordance with IEC62790, lines in accordance with EN50618 must be used